Hi Delta® - Type H
Job:
Engineer:
Contractor:
Prepared By:
Model:
Hydronic Heating Boiler
Models 992BE-2342BE
Date:
87% Efficiency
MBTUH Input:
Indoor/Outdoor:
Š 100% Factory Fire Tested
Š Efficiency: 87%
Š Maximum Outlet Temperature: 230°F
Š Minimum Non-Condensing Inlet Temperature: 120°F
Š Thermal Shock Proof Heat Exchanger
Š Limited Twenty-Year Thermal Shock Warranty
Š Limited Ten-Year Closed-System Heat Exchanger
Warranty
Š Diagnostic Center with Fault History
Š PolyTuf Powder Coated Cabinet
Š No Combustible Floor Shield Required
Š Fan-Assisted
Š Patented Burner Security Blanket
Heat Exchanger
Gas Train
Burner
ƒ
ƒ
H Stamp
Headers
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Manual Gas Shut-Off Valve(s)
ƒ
Ultra-Low NOx: Less than 30 PPM
Gas Pressure Regulator
Safety Shut-Off Valve
Firing Control Valve
Low Gas Pressure Switch, Manual
Firing Mode
Temperature Controls
Glass-Lined Cast Iron – Standard
B- TempTracker Digital Controller,
4-Stage
Y-241 Electronic Sequencer, 4-Stage
Y-281 Electronic Sequencer, 8-Stage
Bronze – Option A-1
ASME Inspected and Stamped
160 PSIG Working Pressure
National Board Approved
Fin Tubing
ƒ
ƒ
ƒ
3-Stage (H8): Model 992BE
4-Stage (H9): Models 1262BE -
2342BE
Options
Copper – Standard
C-6 Ignition Module, Manual Reset
D-21 TruSeal® Direct Vent
F-10 Low Water Cut-Off, Remote
Probe
Cupro Nickel – Option A-3
ASME Steel Tube Sheet
Silicone High Temp. O-Rings
ASME Pressure Relief Valve
60 PSIG – Standard
ƒ
ƒ
Fuel
ƒ
ƒ
ƒ
Natural Gas
Propane Gas
4” WC Gas Supply Pressure
G-20
I-1
High Limit Control, Auto Reset
P-
Pump:
60Hz
HP, 120V, 1∅,
PSIG – Optional
Design Certified ANSI Z21.13/
CSA 4.9
ƒ
ƒ
Temperature and Pressure Gauge
Water Connections
Water Hardness:
Cast Iron
Mounted
GPG
Bronze
Loose
Rear
Construction
ƒ
ƒ
Left – Standard
Right – Option A-6
Indoor/Outdoor Construction
Enclosed Front Controls
Front
P-26 Cold Water Start (See 2000.49)
S-2 High Gas Pressure Switch,
Manual
X-1 SureRack™ Kit
X-2 SureRack Add-on
Controls
Venting
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
120V, 60Hz, 1∅ Power Supply
Vent Location
120/24V 60Hz Transformer
100% Shut-Off/Lockout
Hot Surface Ignition
Top – Standard
Rear – Option D-14
Vent Termination Cap
Outdoor D-11
Indoor, Horizontal D-15
Indoor, Vertical (by others)
Combustion Air
In-Line Filter Kit (TruSeal only)
D-17
Air Intake Elbow D-16
Extractor – Optional
By others
ƒ
Remote Flame Sensor
High Limit Control, Manual Reset
On/Off Power Switch
Manual Shut-Off, Front-Mounted
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switches
Economaster Pump Time Delay
Enable/Disable
Regulatory Agency Requirements
ƒ
ƒ
Not required
Catalog No.: 2000.451E
Effective: 11-15-07
Replaces: 1-1-07
|
Radio Shack Blood Pressure Monitor 63 1514 User Guide
Radio Shack Radar Detector 22 1692 User Guide
RBH Sound Speaker 1001RB User Guide
RCA Clock Radio RC40 User Guide
RCA Flat Panel Television J32BE220 User Guide
RCA Handheld TV E13700 User Guide
RocketFish Home Theater System 09 0474 User Guide
Samsung DVD Recorder DVD R128 X User Guide
SATO Printer S8408 User Guide
Scientific Atlanta Network Router WebSTAR DPX2203 User Guide